Real inputs.
Visible calculations.
Analyze an EEG recording. Inspect a live device stream. Turn saved task sessions into a personal practice plan. Each engine keeps its inputs, quality checks and outputs visible.
Your EEG. A clear connection path.
Choose your device interface, prepare the local connector, then check the incoming signal. A listed connector is not a verified hardware integration.
- 01Choose an input
- 02Set up your computer
- 03Connect and check
Set up the connector on your acquisition computer
Use the computer connected to the EEG headset, not the Noetryx hosting server. Start with a desktop browser on that same computer.
Install Python 3.10 or later and the manufacturer's required drivers.
Download these two files into one folder, together with your connector settings.
Open a terminal in that folder. Create a private Python environment and install the dependencies.
Windows PowerShell
py -3 -m venv .venv .\.venv\Scripts\python.exe -m pip install -r noetryx-connect-requirements.txtmacOS / Linux
python3 -m venv .venv .venv/bin/python -m pip install -r noetryx-connect-requirements.txtConfigure a trusted local TLS certificate. Follow the official mkcert installation guide, then run these commands in the same folder. Installing a local certificate authority changes this computer's trust settings; keep its private key private.
Official local certificate setupmkcert -install mkcert -cert-file noetryx-local.pem -key-file noetryx-local-key.pem localhost 127.0.0.1Generate a private token in the connection panel below. Start the connector and paste the token at its hidden prompt.
Windows PowerShell
.\.venv\Scripts\python.exe noetryx_eeg_bridge.py --config noetryx-device.jsonmacOS / Linux
.venv/bin/python noetryx_eeg_bridge.py --config noetryx-device.jsonReturn to this page, use the local bridge address and the same token, then connect. Allow a browser local-network permission only for your own acquisition computer if requested.
Phone access needs a reachable, trusted bridge hostname configured by your clinic or IT team. The default local address works only on the acquisition computer. Direct phone Bluetooth pairing is not included.
Advanced setup and troubleshootingChoose your device path, then follow the setup steps.
From samples to spectrum.
Bring a recording or your own compatible acquisition bridge. Processing runs on your device. No signal is generated when no data source is connected.
- Secure connection
- Not connected
- Incoming EEG
- Waiting for samples
- Signal quality
- Not checked
- Personal reference
- Not started
These checks describe this connection only. They do not certify the device or establish clinical validity.
No data source. Import an EEG recording or connect a device bridge.
Your signal belongs here.
The waveform, spectrum and measurements appear only after samples pass the input checks.
- Source mode
- —
- Analyzed duration
- —
- Accepted 4 s epochs
- —
- Rejected 4 s epochs
- —
| Band | Frequency | Power µV² | Share of 1–45 Hz |
|---|
Band power is a signal measurement, not an intelligence, concentration, relaxation or brain-health score. Basic screening can miss artifacts.
Compare alpha power with your own reference
Keep the same channel, posture, eyes condition and recording setup. Calibration collects 15 accepted four-second epochs. Rejected epochs do not count.
Connect a device to begin.
No feedback until a reference and a later accepted epoch are available.
This display reflects relative alpha power only. Higher is not necessarily better. It does not prescribe a mental state, stimulation or treatment, and benefit has not been established.
Export contains channel measurements, accepted/rejected epoch reasons, settings and calibration when present. Nothing is saved automatically. Changing source or clearing data removes the current analysis from this page.
What the engine calculates
Four-second epochs are screened for flat signal, repeated samples, large amplitude changes and strong 50/60 Hz contamination. Each spectrum uses Welch’s method: two-second periodic Hann windows, 50% overlap, segment mean removal and one-sided power density.
Recorded-file band summaries average accepted epochs only. Live feedback compares a later accepted epoch with the median alpha share from 60 seconds of accepted calibration data. Feedback stops on stale data, gaps, disconnection or when you leave this tab.
Screening thresholds are disclosed engineering rules. They have not been validated as a medical signal-quality detector. Read the full protocol and limitations.
Your results.
A reasoned next step.
Choose the skill you want to practice. Four specialized software agents check your records, evaluate a personal prediction model, build your next session and review comparable progress. Every output has a visible source.
A plan starts with your evidence.
Complete and save a task, then run the agents. An empty account gets a starting protocol. Model predictions appear only after enough comparable history exists and the learned model beats its baseline.
Start with Focus GridTechnology you can inspect. These are bounded, on-demand software agents implemented in Noetryx's application. The Model agent fits learned numerical weights. Signal, Practice and Review use disclosed rules and statistics. No external chatbot or large language model is involved.
Your latest run is saved with its source revision and cleared when the underlying records change. No brain activity, medical diagnosis or proven training effect is inferred.
Explore the technology and capability status